Fast Cadmium Analysis in Plastics and Polymers With SPECTRO XEPOS
The energy-dispersive XRF system SPECTRO XEPOS has proven to be the ideal instrument for determining cadmium, lead, mercury, and chromium at the limits set for ELV and at the still-to-be-set limits for WEEE. The achieved average detection limit for Cd for measurements of granulated plastic polymers is 8 ppm. Thus, XEPOS can measure comfortably below the limit (100 ppm) set by the ELV directive. Limits can also be optimally monitored for lead, mercury, and chromium. Thanks to the SPECTRO proprietary polarization technology, the limits of detection for individual elements are improved by a factor of 4-7 versus conventional ED-XRF spectromters.
The SPECTRO XEPOS performs a complete multi-element analysis for the heavy metals listed in the directives within 500 seconds and a cadmium-only analysis within 300 seconds. Sample preparation is simple: the material only has to be ground up and then measured as a bulk material.
SPECTRO envisions the fields of application for the XEPOS system to also include, in addition to the automotive industry and their suppliers, the electronics industry, cable importers, compounders, as well as the recycling industry.
Other news from the department research and development
These products might interest you
Eclipse by Wyatt Technology
FFF-MALS system for separation and characterization of macromolecules and nanoparticles
The latest and most innovative FFF system designed for highest usability, robustness and data quality
Spinsolve Benchtop NMR by Magritek
Spinsolve Benchtop NMR
Spinsolve is a revolutionary multinuclear NMR spectrometer that provides the best performance
HYPERION II by Bruker
FT-IR and IR laser imaging (QCL) microscope for research and development
Analyze macroscopic samples with microscopic resolution (5 µm) in seconds
Get the chemical industry in your inbox
By submitting this form you agree that LUMITOS AG will send you the newsletter(s) selected above by email. Your data will not be passed on to third parties. Your data will be stored and processed in accordance with our data protection regulations. LUMITOS may contact you by email for the purpose of advertising or market and opinion surveys. You can revoke your consent at any time without giving reasons to LUMITOS AG, Ernst-Augustin-Str. 2, 12489 Berlin, Germany or by e-mail at revoke@lumitos.com with effect for the future. In addition, each email contains a link to unsubscribe from the corresponding newsletter.