To use all functions of this page, please activate cookies in your browser.
my.chemeurope.com
With an accout for my.chemeurope.com you can always see everything at a glance – and you can configure your own website and individual newsletter.
- My watch list
- My saved searches
- My saved topics
- My newsletter
Rotary compressionA rotary compression pump works in cycles. Over each cycle a volume is created in contact with the cavity where pressure is to be lowered. By random motion, molecules from the vacuum pass into the volume created by the pump. This volume is then cut off from the cavity and compressed in contact with a one way valve. If the volume is compressed enough some of the molecules will pass through the valve. Additional recommended knowledgeThe maximum efficiency of a rotary compression pump is the ratio between the volume in contact with the vacuum and the smallest contracted volume in contact with the valve. If the ratio is 1:1000 and the pump is exhausting to atmospheric pressure, the highest achievable vacuum is 1/1000 of atmospheric pressure. This corresponds to 0.76 Torr or 101.3 Pa. This limitation makes rotary compression pumps very hard to construct if lower pressures than about 1 Torr is to be achieved. The simplicity of the process makes the rotary compression pump cheap and it is widely used as a low vacuum pump or a fore pump to a diffusion pump. See also rotary vane pump |
This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article "Rotary_compression". A list of authors is available in Wikipedia. |